USF1000.txt 1.1 KB

123456789101112131415161718192021222324252627282930313233343536373839404142
  1. 2009-06-20bn
  2. This document describes the protocol for the ultrasound fill-meter USF 1000 S.
  3. Datagram is of FS20 sensor message type:
  4. 81 0C 04 ?? 01 01 A0 01 A5 CE AA 00 cc xx
  5. 81: begin of FS20/FHT communication
  6. 0C: remaining length of datagram (12 bytes)
  7. 04: type of datagram
  8. ??: checksum
  9. 01 01 A0 01: FS20 fix sequence, always 01 01 A0 01
  10. A5 CE: FS20 housecode, always A5CE
  11. AA: FS20 command, always AA
  12. 00: always 00
  13. cc: code, see below
  14. xx: measured distance in cm
  15. code:
  16. hex bin
  17. 37 00110111 30min message interval, normal operation
  18. B7 10110111 3s message interval, normal operation
  19. F7 11110111 3s message interval, battery low
  20. |||+++++-- 0x17 always 0x17
  21. ||+------- 0x20 always 1 (= value byte follows)
  22. |+-------- 0x40 battery warning
  23. +--------- 0x80 test mode (3s message interval)
  24. measured distance from ultrasound sender/transmitter:
  25. distance hex dec
  26. 0.50 m 0x30 48
  27. 1.00 m 0x60 96
  28. 1.50 m 0x92 146
  29. 2.00 m 0xC4 196
  30. It is assumed that xx is the distance in centimeters from the top of the box
  31. (4 cm box height + 1 cm height of ultrasound sender/transmitter).